Cables for Special Applications

SJOOW cables

Rubber service cords with (UL) + c(UL) LISTED approvals. They are resistant to oils, water, UV exposure and suitable for outdoor and hard usages and wet installations.

APPLICATIONS

These jacketed service cords are used for indoor and outdoor electrical power connections requiring high flexibility and time durability and are suitable for both wet and dry locations. They offer an excellent resistance to heat,  oils, water, ozone besides of sunlight, chemicals and abrasion. Typical heavy-duty applications where their use is required include wiring for industrial machinery, large appliances, temporary supply of electrical power and lighting for construction sites. They are often used also in portable equipment and appliances, power extension, small motors and associated machinery.

Cables for Special Applications: SJOOW cables
Tested and Approved as Safe Product
Tested and Approved as Safe Product
Total customizing service
Total customizing service
Excellent performances and High Quality Level
Excellent performances and High Quality Level
Before and Post-Sales Technical Support
Before and Post-Sales Technical Support

Solutions designed for your work

For Immersion in liquids and Lighting and Special applications choose SJOOW cables Salcavi cables

CABLE STRUCTURE

  • Electrolytic flexible bare copper conductor conforming to UL 62 and UL 1581 requirements.
  • EPDM elastomeric rubber conforming to Class 3 of Table 8 of standard UL 62 and resistant to oils contact up to 60°C.
  • The inner cores are twisted together with length of lay conforming to Table 10 of UL 62 standard, wherever it is necessary together with a polyester filler
  • Separator tape.
  • CPE elastomeric rubber conforming to Class 1.4 of Table 11 of standard UL 62, water resistant and oils resistant up to 60°C.
  • Ink-printing : SALCAVI TECHNIC SPA ITALY SJOOW No. of conductors X AWG size 90°C 300V FT2 (UL)c(UL) E212322 –40°C WATER RESISTANT 60°C  OIL RESISTANT 60°C  MONTH/YEAR


Certificates
RoHS
REACH
cULus LISTED
CE


Technical specifications
Short-circuit temperature
Short-circuit temperature
200 °C
Rated temperature
Rated temperature
- 40 ÷ 90 °C ( @ fixed and dry installation) ; - 20 ÷ 90 °C ( for dynamic applications)
Rated voltage
Rated voltage
300 VAC
Water resistance
Water resistance
UL 62 and CSA C22.2 No. 49, Clauses 5.2.4.1 and 5.2.4.2 ; UL 2556 clauses 6.5, 6.6
UV resistance
UV resistance
UL 62 and CSA C22.2 No. 49, Clauses 5.1.1, 5.1.2, 5.1.7 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2
Oil resistance
Oil resistance
UL 62 and CSA C22.2 No. 49 Clauses 5.1.1, 5.1.2 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2
cULus LISTED
cULus LISTED
UL File No. E212322
Weather resistance
Weather resistance
UL 62 and CSA C22.2 No. 49, Clause 5.1.6 ; UL 2556 and CSA C22.2 No. 2556, Clause 7.5
Minimum bending radius
Minimum bending radius
≥ 6 x D ( @ fixed installation, @ 20°C) ≥ 8 x D ( for dynamic applications, @ 20°C )
Test voltage
Test voltage
3000 VAC


Technical sheet
download


Available types of packaging
Rolls
Reels